logo.gif (3614 bytes)

nav_prod.gif (2801 bytes)

CORRIM Company
Oshkosh, Wisconsin

UNDERWRITERS LABORATORIES LABELED
F.R.P. 'POLYFIRE' FIRE DOOR
250° TEMP. RISE FIBERGLASS FIRE DOORS
10-97-1.jpg (12315 bytes)
TESTED IN ACCORDANCE WITH ASTM E-152/UL 10C

 

In accordance with a continuing program of product research and development, CORRIM Company reserves the right to change design and/or details of its products without notice.  All details, drawings and dimensions are accurate for estimating purposes at the time of publication.  Specific information for job details and drawings should be obtained from CORRIM Company offices or distributors. CORRIM Company
Corrosion Immune Fiberglass Doors and Frames
3331 County Road A · Oshkosh, WI   54901-1414
Phone: 920-231-2000  Fax: 920-231-2238
Internet Address: www.corrim.com

Email Address: info@corrim.com

 

TECHNICAL FACT SHEET 10-97

 

1 HOUR FIRE-RATED DOUBLE DOORS
10-97-2.jpg (12124 bytes)
 
  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Gov. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset
  • Gov. 86 mortise lock
  • Cylinder deadlock (1-1/2" bore)
  • Surface Bolts
  • Manual or Automatic Flushbolts
  • Throughbolted Surface Closer
  • Exit Devices: Surface Surface Vertical Rod Vertical Rod Surface Vertical Rod Mortise
  • Viewer (1/2" Max.)
  • Astragals or metal edges are not required.
  • Doors to have intumescent seal applied to all door edges.

 

1-1/2 HOUR FIRE-RATED
DOUBLE DOORS
10-97-2.jpg (12124 bytes)

ASTRAGALS ARE REQUIRED ON PAIRS WITH A LOCK AND FLUSHBOLT OR SURFACE BOLTS AND SURF. VERT./MORT.
10-97-8.jpg (5879 bytes)

 
  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Gov. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset
  • Gov. 86 mortise lock
  • Cylinder deadlock (1-1/2" bore)
  • Surface Bolts
  • Manual or Automatic Flushbolts
  • Throughbolted Surface Closer
  • Exit Devices: Surface Surface Vertical Rod Vertical Rod Surface Vertical Rod Mortise
  • Viewer (1/2" Max.)

 

METAL EDGES ARE REQUIRED ON PAIRS WITH SURF. VERTICAL ROD/SURF. VERTICAL ROD COMBINATION.
10-97-9.jpg (4559 bytes)

 

1 HOUR FIRE-RATED DOORS
10-97-3.jpg (6847 bytes)

 

  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Gov. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset
  • Gov. 86 mortise lock
  • Cylinder deadlock (1-1/2" bore)
  • Rim Panic Devices
  • Mortise Panic Devices
  • Viewer (1/2" Max.)
  • Throughbolted Surface Closer
  • Intumescent seal applied to all door edges.

 

1-1/2 HOUR FIRE-RATED DOORS
10-97-3.jpg (6847 bytes)
  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Gov. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset
  • Gov. 86 mortise lock
  • Cylinder deadlock (1-1/2" bore)
  • Rim Panic Devices
  • Mortise Panic Devices
  • Viewer (1/2" Max.)
  • Throughbolted Surface Closer
  • Intumescent seal applied to all door edges.
 

20 MINUTE FIRE-RATED
DOUBLE DOORS AND FRAMES
10-97-4.jpg (7052 bytes)

  • Smooth and pebble face sheets.
  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Four inch header.
  • GOV. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset.
  • GOV. 86 mortise lock.
  • Cylinder deadlock (1-1/2" bore).
  • Surface bolts.
  • Manual or automatic flushbolts.
  • Surface closer.
  • Exit devices:
    Surface          /Surface
    Vertical Rod  / Vertical Rod
    Surface         / Mortise
    Vertical Rod  /
  • Viewer (1/2" Max.)
  • Astragals or metal edges are required.
 

20 MINUTE FIRE-RATED
DOORS AND FRAMES
10-97-5.jpg (8308 bytes)

  • Smooth and pebble face sheets.
  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Four inch header.
  • GOV. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset.
  • GOV. 86 mortise lock.
  • Cylinder deadlock (1-1/2" bore).
  • Rim panic devices.
  • Mortise panic devices.
  • Viewer (1/2" Max.)
  • Surface closer
  • Wide variety of jamb depths
 

1/2 AND 3/4 HOUR FIRE-RATED
DOUBLE DOORS
10-97-6.jpg (10134 bytes)

  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Four inch header.
  • GOV. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset.
  • GOV. 86 mortise lock.
  • Cylinder deadlock (1-1/2" bore).
  • Surface bolts.
  • Manual or automatic flushbolts.
  • Throughbolted surface closer.
  • Exit devices:
    Surface          /Surface
    Vertical Rod  / Vertical Rod
    Surface         / Mortise
    Vertical Rod  /
  • Viewer (1/2" Max.)
  • Astragals or metal edges are not required.
  • Doors to have intumescent seal applied to all door edges.
 

1/2 AND 3/4 HOUR
FIRE-RATED DOORS
10-97-7.jpg (7779 bytes)

  • Throughbolted full surface or half surface continuous hinge.
  • Full mortise hinges 4-1/2" & 5" standard or heavyweight.
  • Four inch header.
  • GOV. 161 cylinder lock 2-3/8", 2-3/4" or 5" backset.
  • GOV. 86 mortise lock.
  • Cylinder deadlock (1-1/2" bore).
  • Rim panic devices.
  • Mortise panic devices.
  • Viewer (1/2" Max.)
  • Throughbolted surface closer.
  • Doors to have intumescent seal applied to all door edges.
SPECIFICATIONS FOR UL DOORS
1.0  GENERAL

Doors shall be furnished by CORRIM Company in strict accordance with the procedures approved by Underwriter's Laboratories, Inc.  Installation shall be by the general contractor in strict accordance with manufacturer's recommendations and instructions.

2.0  FRP FACE SHEETS

2.1  FRP FACE SHEETS

FRP face sheets shall be made from glass reinforced engineered resins.

2.2  FINISH

  • White color impregnated gelcoat
  • Gray color impregnated gelcoat
  • Special colors upon request
  • Smooth seamless matte finish
3.0  INTERNAL CONSTRUCTION

3.1  CORE
      1-1/2 hour rated mineral core

3.2  STILES & RAILS

Stiles and rails are fabricated from pultruded fire retardant materials.

3.3  SEALS

Intumescent seals are factory applied around the perimeter of the fire doors.

ALL FIRE DOORS SHALL HAVE A UL FIRE DOOR LABEL ATTACHED TO THE HINGE EDGE OF THE DOOR APPROXIMATELY 60" FROM THE BOTTOM OF THE DOOR.
THIS LABEL MUST NOT BE REMOVED.

ALL FIRE DOORS ARE REQUIRED TO BE INSTALLED IN A UL LABELED STEEL DOOR FRAME.  FRAMES ARE GELCOATED TO MATCH DOORS.


AVAILABLE OPTIONS:
  • APPLIED MOULDING (WOOD)
  • FUSIBLE LINK LOUVERS
  • GELCOATED MVF'S TO MATCH DOORS
  • STAINLESS STEEL MVF'S
  • STAINLESS STEEL DOOR FRAMES
  • METAL EDGES IN LIEU OF A METAL ASTRAGAL
    (FOR VERTICAL ROD EXIT DEVICES)